Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
bioRxiv ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38562889

RESUMO

Wound infections, exacerbated by the prevalence of antibiotic-resistant bacterial pathogens, necessitate innovative antimicrobial approaches. Polymicrobial infections, often involving Pseudomonas aeruginosa and methicillin-resistant Staphylococcus aureus (MRSA), present formidable challenges due to biofilm formation and antibiotic resistance. Hypochlorous acid (HOCl), a potent antimicrobial agent produced naturally by the immune system, holds promise as an alternative therapy. An electrochemical bandage (e-bandage) that generates HOCl in situ was evaluated for treatment of murine wound biofilm infections containing both MRSA and P. aeruginosa with "difficult-to-treat" resistance. Previously, the HOCl-producing e-bandage was shown to reduce wound biofilms containing P. aeruginosa alone. Compared to non-polarized e-bandage (no HOCl production) and Tegaderm only controls, the polarized e-bandages reduced bacterial loads in wounds infected with MRSA plus P. aeruginosa (MRSA: vs Tegaderm only - 1.4 log10 CFU/g, p = 0.0015, vs. non-polarized - 1.1 log10 CFU/g, p = 0.026. P. aeruginosa: vs Tegaderm only - 1.6 log10 CFU/g, p = 0.0015, vs non-polarized - 1.6 log10 CFU/g, p = 0.0032), and MRSA alone (vs Tegaderm only - 1.3 log10 CFU/g, p = 0.0048, vs. non-polarized - 1.1 log10 CFU/g, p = 0.0048), without compromising wound healing or causing tissue toxicity. Addition of systemic antibiotics did not enhance the antimicrobial efficacy of e-bandages, highlighting their potential as standalone therapies. This study provides additional evidence for the HOCl-producing e-bandage as a novel antimicrobial strategy for managing wound infections, including in the context of antibiotic resistance and polymicrobial infections.

2.
bioRxiv ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38585771

RESUMO

Electrochemical bandages (e-bandages) can be applied to biofilm-infected wounds to generate reactive oxygen species, such as hypochlorous acid (HOCl) or hydrogen peroxide (H 2 O 2 ). The e-bandage-generated HOCl or H 2 O 2 kills biofilms in vitro and in infected wounds on mice. The HOCl-generating e-bandage is more active against biofilms in vitro , although this distinction is less apparent in vivo . The H 2 O 2 -generating e-bandage, more than the HOCl-generating e-bandage, is associated with improved healing of infected wounds. A strategy in which H 2 O 2 and HOCl are generated alternately-for dual action-was explored. The goal was to develop a programmable multimodal wearable potentiostat (PMWP) that could be programmed to generate HOCl or H 2 O 2 , as needed. An ultralow-power microcontroller unit managed operation of the PMWP. The system was operated with a 260-mAh capacity coin battery and weighed 4.6 grams, making it suitable for small animal experiments or human use. The overall cost of a single wearable potentiostat was $6.50 (USD). The device was verified using established electrochemical systems and functioned comparably to a commercial potentiostat. To determine antimicrobial effectiveness, PMWP-controlled e-bandages were tested against clinical isolates of four prevalent chronic wound bacterial pathogens, methicillin-resistant Staphylococcus aureus (MRSA), Pseudomonas aeruginosa, Acinetobacter baumannii , and Enterococcus faecium , and one fungal pathogen of emerging concern, Candida auris . PMWP-controlled e-bandages exhibited broad-spectrum activity against biofilms of all study isolates tested when programmed to deliver HOCl followed by H 2 O 2 . These results show that the PMWP operates effectively and is suitable for animal testing.

3.
Antimicrob Agents Chemother ; 68(2): e0121623, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38214514

RESUMO

The growing threat of antibiotic-resistant bacterial pathogens necessitates the development of alternative antimicrobial approaches. This is particularly true for chronic wound infections, which commonly harbor biofilm-dwelling bacteria. A novel electrochemical bandage (e-bandage) delivering low-levels of hypochlorous acid (HOCl) was evaluated against Pseudomonas aeruginosa murine wound biofilms. 5 mm skin wounds were created on the dorsum of mice and infected with 106 colony-forming units (CFU) of P. aeruginosa. Biofilms were formed over 2 days, after which e-bandages were placed on the wound beds and covered with Tegaderm. Mice were administered Tegaderm-only (control), non-polarized e-bandage (no HOCl production), or polarized e-bandage (using an HOCl-producing potentiostat), with or without systemic amikacin. Purulence and wound areas were measured before and after treatment. After 48 hours, wounds were harvested for bacterial quantification. Forty-eight hours of polarized e-bandage treatment resulted in mean biofilm reductions of 1.4 log10 CFUs/g (P = 0.0107) vs non-polarized controls and 2.2 log10 CFU/g (P = 0.004) vs Tegaderm-only controls. Amikacin improved CFU reduction in Tegaderm-only (P = 0.0045) and non-polarized control groups (P = 0.0312) but not in the polarized group (P = 0.3876). Compared to the Tegaderm-only group, there was less purulence in the polarized group (P = 0.009). Wound closure was neither impeded nor improved by either polarized or non-polarized e-bandage treatment. Concurrent amikacin did not impact wound closure or purulence. In conclusion, an HOCl-producing e-bandage reduced P. aeruginosa in wound biofilms with no impairment in wound healing, representing a promising antibiotic-free approach for addressing wound infection.


Assuntos
Infecções por Pseudomonas , Infecção dos Ferimentos , Animais , Camundongos , Pseudomonas aeruginosa , Ácido Hipocloroso , Amicacina , Infecções por Pseudomonas/microbiologia , Infecção dos Ferimentos/microbiologia , Bandagens , Antibacterianos , Biofilmes
4.
bioRxiv ; 2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37790575

RESUMO

A novel electrochemical bandage (e-bandage) delivering low-level hypochlorous acid (HOCl) was evaluated against Pseudomonas aeruginosa murine wound biofilms. 5 mm skin wounds were created on the dorsum of Swiss-Webster mice and infected with 10 6 colony forming units (CFU) of P. aeruginosa . Biofilms were formed over two days, after which e-bandages were placed on the wound beds and covered with Tegaderm™. Mice were administered Tegaderm-only (control), non-polarized e-bandage (no HOCl production), or polarized e-bandage (using an HOCl-producing potentiostat), with or without concurrently administered systemic amikacin. Purulence and wound areas were measured before and after treatment. After 48 hours, animals were sacrificed, and wounds were harvested for bacterial quantification. Forty-eight hours of polarized e-bandage treatment resulted in mean biofilm reductions of 1.4 log 10 CFUs/g (9.0 vs 7.6 log 10 ; p = 0.0107) vs non-polarized controls, and 2.2 log 10 CFU/g (9.8 vs 7.6 log 10 ; p = 0.004) vs Tegaderm only controls. Systemic amikacin improved CFU reduction in Tegaderm-only (p = 0.0045) and non-polarized control groups (p = 0.0312), but not in the polarized group (p = 0.3876). Compared to the Tegaderm only group, there was more purulence reduction in the polarized group (p = 0.009), but not in the non-polarized group (p = 0.064). Wound closure was not impeded or improved by either polarized or non-polarized e-bandage treatment. Concurrent amikacin did not impact wound closure or purulence. In conclusion, an HOCl-producing e-bandage reduced P. aeruginosa in wound biofilms with no impairment in wound healing, representing a promising antibiotic-free approach for addressing wound infections.

5.
IEEE Trans Biomed Eng ; 70(3): 954-961, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36103447

RESUMO

OBJECTIVE: Wound healing is accelerated when Platelet Rich Plasma is activated and growth factors are released. In this study, it was aimed to stimulate platelets without using chemical stimulants. METHOD: Two types of mechanical platelet activation methods have been proposed in this study. The first one is a microfluidic chip developed with the shear-induced platelet activation approach. The second one is a piezo-based ultrasound-assisted device which provides platelet activation by stimulating with an ultrasonic wave (0.55 and 1.1 MHz). Three different microfluidic chip designs were worked out to determine the optimal shear stress characteristics; 8-nodes (2789 µs, 288 shear pulses, and 98.3 dyne/cm2), 40-nodes (2765 µs, 1440 shear pulses, and 95.5 dyne/cm2) and pillar-shaped (1030 µs, 1656 shear pulses, and 48.1 dyne/cm2). RESULTS: The highest platelet activation rate (72.7%) was obtained from the chips with 8-nodes. In the ultrasound-assisted device, 32.4% activation rate was obtained from ultrasound waves with 0.55 MHz frequency and 10 Vp-p amplitude. These activation rates, determined by CD62P (P-Selectin) expression, are significantly higher than spontaneous activation of intact platelets (8.5%). In addition, the gradual increase in activation of stimulated platelets with incubation at room temperature showed that activation continued after stimulation. CONCLUSION: The results showed that these microfluidic devices can be used for platelet activation to enhance the effect of PRP treatment and might reduce adverse immune reactions that may happened due to the use of exogenous activator substances. SIGNIFICANCE: Fast-response, low-cost, easy-to-use and controllable biomedical device have been developed for PRP applications.


Assuntos
Ativação Plaquetária , Plasma Rico em Plaquetas , Plaquetas/metabolismo , Dispositivos Lab-On-A-Chip , Plasma Rico em Plaquetas/metabolismo , Estresse Mecânico
6.
Sensors (Basel) ; 20(10)2020 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-32455546

RESUMO

This study presents the design and fabrication of a flexible tactile sensor printed on a cellulose paper substrate using a carbon black (CB) - filled polyvinyl alcohol (PVA) polymer matrix as ink material. In the design, electrodes are obtained by screen printing of CB/PVA composite on dielectric cellulose paper. The screen-printing method is preferred for fabrication because of its simplicity and low manufacturing cost. The tactile sensor is formed by overlapping two ink-printed sheets. Electrical properties are investigated under compressive and tensile strains. The results indicate that the tactile sensor configuration and materials can be used for piezoresistive, capacitive, and also impedance sensors. The same tactile sensor structure is also examined using a commercial carbon-based ink for performance comparison. The comparative study indicates that CB/PVA ink screen-printed on paper demonstrates superior sensitivity for capacitive sensing with low hysteresis, as well as low response and recovery times. The piezoresistive-sensing properties of CB/PVA on cellulose paper show a gauge factor (GF) of 10.68, which is also very promising when conventional metal strain gauges are considered. CB/PVA screen-printed on cellulose paper features impedance-sensing properties and is also sensitive to the measurement frequency. Therefore, the response type of the sensor can be altered with the frequency.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...